BARRIER AGAINST RISING DAMP

InjectCream

Ready-to-use injection cream for creating a horizontal barrier that limits capillary rising damp in masonry. Applied from the bottom of prepared boreholes.

Key parameters
Base / formSilane-siloxane cream; ready for application
ObjectiveLimiting capillary moisture transport in masonry
Active substance content80%
Density according to the TDS0.88 g/cm³; measurement temperature not stated
Application temperatureMaterial, ambient and substrate temperature +5 to +30°C
Delivery methodManual or pneumatic cream pump with a tube reaching the bottom of the hole

Applications and selection criteria ↓

Technical data

Read values together with the temperature, material state and test conditions.

InjectCream — material data
Consistency / colourCream; white, transparent after drying
Active substance80%
Density in the TDS0.88 g/cm³
Recommended boreholesDiameter 12–14 mm; spacing every 10 cm
Hole depthWall thickness minus 2–4 cm
Drilling direction and levelHorizontally, in the lowest mortar joint

Dimensions are TDS recommendations for this method. Hollow masonry, voids, variable absorbency and discontinuous mortar joints require separate assessment. The calculator gives a borehole quantity estimate; actual consumption also depends on the masonry structure.

Storage and shelf life
+5 to +30°C, protect from frost; 6 months in the original, unopened packaging.

Applications and selection criteria

First establish the repair objective, substrate condition, presence of water and joint movement.

01

Masonry affected by capillary rising damp

Indoor and outdoor use; brick, clinker, blocks, stone and hollow materials specified in the TDS. First confirm the cause of dampness.

02

Continuous horizontal barrier

Select the level and continuity through the thickness and wall junctions. For low-absorbency masonry, the TDS provides for consideration of a double-row arrangement.

Application conditions and limitations

InjectCream does not protect against water under pressure. The barrier does not eliminate condensation, leaking drainage or lateral water ingress. Cream curing and drying of the entire wall are different processes; plan ventilation and an appropriate surface finish.

How the material behaves

Damp masonry with capillary rising damp; not protection against water under pressure. Not a filling material for a moving joint.

1. Ready-to-use cream

No added water or mixing

2. Borehole in a mortar joint

Filling from the bottom

3. Masonry zone

Limiting capillary transport

Cream is introduced into holes in the mortar joint to create a continuous barrier that limits capillary transport. Filling from the bottom while withdrawing the tube reduces air pockets. This is a barrier against rising damp, not standalone protection against water under pressure. The illustration shows the principle of the method; it is not a test result for this product.
Diagram key

Drill in the mortar joint. Hole diameter: Ø12 mm; horizontal spacing: 10 cm. The arrow along the hole marks a depth equal to wall thickness minus 4 cm. InjectCream fills the hole; CrackOn.5 identifies the hole-sealing material. Pump: PUMP INTEGRALE 800.

Preparation and application

Work sequence after assessing the structure and selecting the method. Full requirements are given in the product instructions.

  1. Assess dampness

    Check capillary rising damp and the condition of gutters and drainage. Repair sources of ingress and plan how to deal with salt-contaminated or damp plaster.

  2. Drill and clean holes

    Drill horizontally into the mortar joint according to the TDS. Remove dust with compressed air. Check whether masonry voids interfere with the intended filling.

  3. Apply cream from the bottom

    Use a cream pump and a tube reaching the bottom. Slowly withdraw the tube as material is injected to fill the hole evenly and reduce air pockets.

  4. Close holes and plan drying

    The TDS specifies CrackOn.5 for closing holes. Use the specified finish and ventilation. Clean tools with warm water, with detergent if necessary.

Product documentation

Data, application instructions and safety documents for the supplied material.

Preparing for safe work

Before use, read the current documentation for all supplied components. Select protective equipment, ventilation and cleaning methods appropriate to the material and equipment.

Discuss your project conditions

Prepare a description of the substrate, water, geometry and expected result. Let us select the material and delivery method.

Discuss your project / technical selection ↗